MElectronic Flow Switches from Ameritrol
1-800-910-6689
sales@ameritrol.com
1185L Park Center Dr
Vista, CA 92081
Mon-Fri 8am - 4:30pm
Pacific Time
HOME
ABOUT
PRODUCTS
APPLICATIONS
LITERATURE
ORDER ONLINE/ RFQ
Home > Flow Switches > SX Series
SX Series SX Series Brochure
Flow Switches
   FX Series
   FM Series
   FD Series
   IX Series
   IM Series
   SX Series
   QX Series

Level Switches
   LX Series
   LM Series
   LD Series
   SL Series
   QL Series

Temperature Switches
   TX Series
   TM Series
Flow Switches SX Series

FROM $750.00

ORDER ONLINE/ RFQ
FEATURES
  • Tri-Clamp Style Process Connection

  • 3A Sanitary Design

  • 316L Stainless Steel with Electropolish Option

  • Temperatures to 350F

  • Low Velocity Detection

  • No Moving Parts for Reliable Results

  • Pressures to 2,000 PSIG

  • Field Programmable Relay Energization
OPERATIONS

The SX series sanitary flow switch has been designed to meet the most critical flow detection applications in the food, pharmaceutical, biotechnology, and water treatment industries. Quick disconnect tri-clamp caps are standard with special finishes for 3A applications and polished/electropolished for biotechnology and pharmaceutical use.

The thermal dispersion principle of operation features no moving parts exposed to the process and 316L Stainless Steel is standard for all wetted surfaces. The instrument operates by measuring a temperature differential between a heated and a reference temperature sensor. An extremely low power heating element is attached to a temperature sensor while a second temperature sensor is isolated from the heater to provide compensation for changing process temperature. The electronics measure the differential and can be adjusted to switch at any flow listed in the flow switch set-point range chart.

Extremely low flow rates such as 0.04 GPM in a 1” line can be detected with rangeability up to 300:1. These flow switches can be used in virtually all liquids, slurries, and gasses.

The electronics are available in several different configurations including single or dual switch points. Temperature monitoring is available with either a switch output or a linear 4-20 mA output. Relay outputs are standard and are offered with several different configurations and either 3 or 10 amp contact ratings. Remote mounting of the electronics is also available.

For more information please download a brochure, call us at 1-800-910-6689, or use our part number configurator to Request a Quotation.
APPLICATIONS
  • Suitable for CIP systems
  • UV Systems: Verifies flow for save operation of UV systems
  • Pump Protection: Automatic shut down on low flow or no flow
  • Control Rooms: Verifies flow of pumps or if valves are energized
  • Reliably used in extremely viscous fluids
  • Deionized / Ultrapure Water Flow Sensor
  • Agitation Monitor: Positive indication of agitation in tanks or vessels
NAVIGATION CONTACT LOCATION

Home
Products
     Flow Switches
     Level Switches
     Temperature Switches
Literature
Order Online / RAQ
About Us

Toll free: 1-800-910-6689
Voice: 760-727-7273
Fax: 760-727-7151
E-mail: sales@ameritrol.com

Ameritrol Inc.
1185L Park Center Dr.
Vista, CA 92081


© 2024, Ameritrol, Inc. All Rights Reserved.
MElectronic Flow Switches from Ameritrol
1-800-910-6689
sales@ameritrol.com
Home > Flow Switches > SX Series
SX Series
SX Series Brochure
Flow Switches
   FX Series
   FM Series
   FD Series
   IX Series
   IM Series
   SX Series
   QX Series
Level Switches
   LX Series
   LM Series
   LD Series
   SL Series
   QL Series
Temperature Switches
   TX Series
   TM Series


Flow Switches SX Series

Flow Switches SX Series

Flow Switches SX Series
FROM $750.00

ORDER ONLINE/ RFQ



FEATURES
  • Tri-Clamp Style Process Connection

  • 3A Sanitary Design

  • 316L Stainless Steel with Electropolish Option

  • Temperatures to 350F

  • Low Velocity Detection

  • No Moving Parts for Reliable Results

  • Pressures to 2,000 PSIG

  • Field Programmable Relay Energization

OPERATIONS

The SX series sanitary flow switch has been designed to meet the most critical flow detection applications in the food, pharmaceutical, biotechnology, and water treatment industries. Quick disconnect tri-clamp caps are standard with special finishes for 3A applications and polished/electropolished for biotechnology and pharmaceutical use.

The thermal dispersion principle of operation features no moving parts exposed to the process and 316L Stainless Steel is standard for all wetted surfaces. The instrument operates by measuring a temperature differential between a heated and a reference temperature sensor. An extremely low power heating element is attached to a temperature sensor while a second temperature sensor is isolated from the heater to provide compensation for changing process temperature. The electronics measure the differential and can be adjusted to switch at any flow listed in the flow switch set-point range chart.

Extremely low flow rates such as 0.04 GPM in a 1” line can be detected with rangeability up to 300:1. These flow switches can be used in virtually all liquids, slurries, and gasses.

The electronics are available in several different configurations including single or dual switch points. Temperature monitoring is available with either a switch output or a linear 4-20 mA output. Relay outputs are standard and are offered with several different configurations and either 3 or 10 amp contact ratings. Remote mounting of the electronics is also available.

For more information please download a brochure, call us at 1-800-910-6689, or use our part number configurator to Request a Quotation.



APPLICATIONS
  • Suitable for CIP systems
  • UV Systems: Verifies flow for save operation of UV systems
  • Pump Protection: Automatic shut down on low flow or no flow
  • Control Rooms: Verifies flow of pumps or if valves are energized
  • Reliably used in extremely viscous fluids
  • Deionized / Ultrapure Water Flow Sensor
  • Agitation Monitor: Positive indication of agitation in tanks or vessels
NAVIGATION

Home
Products
     Flow Switches
     Level Switches
     Temperature Switches
Literature
Order Online / RAQ
About Us
CONTACT

Toll free: 1-800-910-6689
Voice: 760-727-7273
Fax: 760-727-7151
E-mail: sales@ameritrol.com
LOCATION

Ameritrol Inc.
1185L Park Center Dr.
Vista, CA 92081


© 2022, Ameritrol, Inc. All Rights Reserved.